Warranty: |
One-year |
Battery Life: |
Alkaline 40 hours, approx. |
Size: |
(WxHxD): 240 x 106 x 40 mm |
Weight: |
420 g |
Safety: |
CAT III 1000 V rated |
AC Current (40-400 Hz) Ranges: |
|
400 A, 1000 A |
AC Current (40-400 Hz) Accuracy: |
|
0 - 40 A ± (1.9 % rdg + 8 dgts) |
AC Current (40-400 Hz) Accuracy: |
|
40 - 400 A ± (1.9 % rdg + 7 dgts) |
AC Current (40-400 Hz) Accuracy: |
|
400 - 1000 A ± (2.9 % rdg + 5 dgts) |
AC Current (40-400 Hz) Crest Factor: |
|
(C.F. 1.4 to 2.0) + (1.0 % rgd) |
AC Current (40-400 Hz) Crest Factor: |
|
(C.F. 2.0 to 2.5) + (2.5 % rgd) |
AC Current (40-400 Hz) Crest Factor: |
|
(C.F. 2.5 to 3.0) + (4.0 % rgd) |
AC Current (40-400 Hz) Position Error: |
|
± (1.0 % rdg) |
AC Current (40-400 Hz) Resolution: |
|
0.1 A in 400 A range |
AC Current (Peak Hold) Ranges: |
|
Low, High |
AC Current (Peak Hold) Accuracy: |
|
± (3.0 % rdg + 10 dgts) |
AC Current (Peak Hold) Resolution: |
|
0.1 A in Low range |
DC Current Ranges: |
|
400 A, 1000 A |
DC Current Accuracy: |
|
0 - 100 A ± (2.9 % rdg + 8 dgts) |
DC Current Accuracy: |
|
100 - 400 A ± (1.9 % rdg + 5 dgts) |
DC Current Accuracy: |
|
400 - 1000 A ± (2.9 % rdg + 5 dgts) |
DC Current Position Error: |
|
± (1.0 % rdg) |
DC Current Resolution: |
|
0.1 A in 400 A range |
Frequency Ranges: |
|
4 kHz, 10 kHz |
Frequency Accuracy: |
|
± (0.5 % rdg + 3 dgts) |
Frequency Resolution: |
|
1 Hz in 4 kHz range |
Min. Input Frequency: |
|
20 Hz |
Sensitivity: |
|
< 1 kHz 6 A rms 1 – 10 kHz 10 A rms |